The Pulmonary Artery Catheter

do) have more specific and immediate goals other than life or death. In the case of a monitoring device, the goal is to provide clinical infor- mation, and the PA catheter achieves this goal with distinction.

REFERENCES 1. Swan HJ. The pulmonary artery catheter. Dis Mon 1991; 37:473–543. 2. The ESCAPE Investigators. Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: the ESCAPE trial. JAMA 2005; 294:1625–1633. 3. The NHLBI Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network. Pulmonary artery versus central venous catheter to guide treat- ment of acute lung injury. N Engl J Med 2006; 354:2213–2224. 4. Harvey S, Young D, Brampton W, et al. Pulmonary artery catheters for adult patients in intensive care. Cochrane Database Syst Rev 2006; 3:CD003408. 5. Chatterjee K. The Swan-Ganz catheters: past, present, and future. Circulation 2009; 119:147–152. 6. Kahwash R, Leier CV, Miller L. Role of pulmonary artery catheter in diagno- sis and management of heart failure. Cardiol Clin 2011; 29:281–288. 7. O’Quin R, Marini JJ. Pulmonary artery occlusion pressure: clinical physiolo- gy, measurement, and interpretation. Am Rev Respir Dis 1983; 128:319–326. 8. Nemens EJ, Woods SL. Normal fluctuations in pulmonary artery and pul- monary capillary wedge pressures in acutely ill patients. Heart Lung 1982; 11:393–398. 9. Cope DK, Grimbert F, Downey JM, et al. Pulmonary capillary pressure: a review. Crit Care Med 1992; 20:1043–1056. 10. Pinsky MR. Hemodynamic monitoring in the intensive care unit. Clin Chest Med 2003; 24:549–560. 11. Tracey WR, Hamilton JT, Craig ID, Paterson NAM. Effect of endothelial injury on the responses of isolated guinea pig pulmonary venules to reduced oxygen tension. J Appl Physiol 1989; 67:2147–2153. 12. Kloess T, Birkenhauer U, Kottler B. Pulmonary pressure–flow relationship and peripheral oxygen supply in ARDS due to bacterial sepsis. Second Vienna Shock Forum, 1989:175–180. 13. Bernard GR, Artigas A, Brigham KL, et al. The American–European Consen- sus Conference on ARDS: definitions, mechanisms, relevant outcomes, and clinical trial coordination. Am Rev Respir Crit Care Med 1994; 149:818–824. 14. Nadeau S, Noble WH. Limitations of cardiac output measurement by ther- modilution. Can J Anesth 1986; 33:780–784. 15. Sasse SA, Chen PA, Berry RB, et al. Variability of cardiac output over time in medical intensive care unit patients. Chest 1994; 22:225–232. 16. Konishi T, Nakamura Y, Morii I, et al. Comparison of thermodilution and Fick methods for measurement of cardiac output in tricuspid regurgitation. Am J Cardiol 1992; 70:538–540.

Made with